Monitoring of physical access includes publicly accessible areas within organizational facilities. This can be accomplished, for example, by the employment of guards; the use of sensor devices; or the use of video surveillance equipment such as cameras. Examples of support infrastructure include system distribution, transmission, and power lines. Security controls applied to the support infrastructure prevent accidental damage, disruption, and physical tampering. Such controls may also be necessary to prevent eavesdropping or modification of unencrypted transmissions. Physical access controls to support infrastructure include locked wiring closets; disconnected or locked spare jacks; protection of cabling by conduit or cable trays; and wiretapping sensors.
FURTHER DISCUSSION
The infrastructure inside of a facility, such as power and network cables, is protected so that visitors and unauthorized employees cannot access it. The protection is also monitored by security guards, video cameras, sensors, or alarms.
Example
You are responsible for protecting your IT facilities. You install video cameras at each entrance and exit, connect them to a video recorder, and show the camera feeds on a display at the reception desk [c,d]. You also make sure there are secure locks on all entrances, exits, and windows to the facilities [a,b].
Potential Considerations
Is physical access monitored to detect and respond to physical security incidents [c, d]?58
Copyright
Copyright 2020, 2021 Carnegie Mellon University and The Johns Hopkins University Applied Physics Laboratory LLC.
Copyright 2021 Futures, Inc.
This material is based upon work funded and supported by the Department of Defense under Contract No. FA8702-15-D-0002 with Carnegie Mellon University for the operation of the Software Engineering Institute, a federally funded research and development center, and under Contract No. HQ0034-13-D-0003 and Contract No. N00024-13-D-6400 with the Johns Hopkins University Applied Physics Laboratory LLC, a University Affiliated Research Center.
The view, opinions, and/or findings contained in this material are those of the author(s) and should not be construed as an official Government position, policy, or decision, unless designated by other documentation.
NO WARRANTY. THIS MATERIAL IS FURNISHED ON AN “AS-IS” BASIS. CARNEGIE MELLON UNIVERSITY AND THE JOHNS HOPKINS UNIVERSITY APPLIED PHYSICS LABORATORY LLC MAKE NO WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, AS TO ANY MATTER INCLUDING, BUT NOT LIMITED TO, WARRANTY OF FITNESS FOR PURPOSE OR MERCHANTABILITY, EXCLUSIVITY, OR RESULTS OBTAINED FROM USE OF THE MATERIAL NOR ANY WARRANTY OF ANY KIND WITH RESPECT TO FREEDOM FROM PATENT, TRADEMARK, OR COPYRIGHT INFRINGEMENT.